Detailed Product Description
Phocos solar charge controller
Specification
Type
|
CML 05
|
System Voltage
|
12/24 V auto recognition
|
Max. Charge/Load Current
|
5 A
|
Float Charge
|
13.7/27.4 V (25°C)
|
Boost Charge
|
14.4/28.8 V (25°C), 2Std.
Activation:battery voltage<12.3/24
|
Equalization
|
14.4/29.6 V (25°C), 2Std.
Activation:battery voltage<12.1/24
|
Deep Discharge Protection
State if Charge Dependent
Voltage Dependent
Reconnect Level
|
11.4-11.9 V/ 22.8-23.8 V
11.0/22.0 V
12.8/25.6 V
|
Overvoltage Protection
|
15.5/31.0 V
|
Undervoltage Protection
|
10.5/21.0 V
|
Max.Panel Voltage
(Overvoltage Protection by Varistor)
|
30V in 12 V system
50 V in 24 V system
|
Temperature Compensation(Charge Voltage)
|
-25 mV/K at 12 V
-50 mV/K at 24 V
|
Max.Self Consumption
|
<4 mA
|
Grounding
|
Positive grounding possible
|
Ambient Temperature
|
-40 to +50°C
|
Max. Height
|
4,000 m above sea level
|
Battery Type
|
Lead acid (GEL,AGM flooded)
|
Wire Cross Section
|
< 16 mm²
|
Weight
|
160 g
|
Dimension(B×H×T)
|
80×100×32 mm
|
Type of Protection
|
IP 22
|
Feature
1.Battery state of charge display with 3 LEDs
2.Acoustic load disconnect pre-warning
3.PWM-regulation
4.Boost, equalize and float charging, also for VRLA
5.Automatic 12/24 V detection
6.Integrated temperature compensation
7.Large terminals (up to 16 mm² wire size)
8.SOC and voltage controller LVD
9.Fully electronically protected
|