Humidity Module
  Posting Date : 2024-05-03 17:16:16

Detailed Product Description

 Humidity Module

1.Application:suitable formeter, humidifier, dehumidifier, air-conditioning andother equipment, industrial machinery, electrical automation, meteorology, agricultureand other industries。

2.Parameters
No.  Type          Parameter difference
1    KHTM-01/A     Output 0-3V
2    KHTM-01/B     Output 0-1V
3    KHTM-01/A(B) T,   0-1V

3.ElectricalSpecification

1)  Sensitivecompotent(humidity):macromolecuer humicap capacity “HS1101”
2)  Power:5V±5%
3)  Currentcomsuption:5mA max.(2mAavg.)
4)  Working range:T:emperature 0~60℃  Humidity: 10%~ 95%RH below
5)  Storgeconditions:Temperature:-20~70℃  Humidity: 95%RH below
6)  Humiditytransmission rang: 0~100%RH
7)  Humidityaccurrancy:±5%RH (temperature:25℃,inputvoltage=5V)
8)  Outputsingal:

1)Type: KHTM-01/A , 25℃,input voltage =5V below
Humidty(%): 10 20 30 40 50 60 7080 90
Outut singal: 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7
2) Type:HTM-01/B ,25℃,inputvoltage=5V below
Humdity(%): 10 20 30 40 50 60 7080 90
Output singal:0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
9)Temperature coefficient: ±5%RH (input voltage=5V,30~90%RH, temperaturerange:10~40℃,fiducialpoint:25℃)
10)Power voltage coefficent:±5%RH (input voltage=5V,30~80%RH,  voltage range:4.75~5.25V)
11)Sensitivecompotent(temperature):NTC sensitive resistance
12)Tempertureoutput singal:negativetemperature coefficient thermistor (NEC,chip installaiton:0805encapsulation).Resistance and B value can be selected by customers’ requirment.NTC can be available. For example:10K3% B Value 3950
Temperature(℃) 0 5 10 1520 25 30 35 40 45 50 55 60
Output(K Ω) 165.9 128.6 100.4 79.0162.63 50 40.19 32.51 26.46 21.67 17.85 14.78 12.31

4.Standard testcondition
1) Testing condition: normal temperature:25℃, voltage:5V
Put tempertaure and humidity module in 20%RH below humidity environment for 30minutes.Then put it in testing humidity environment for 15 minutes to testmodule voltage.
2) Testinginstrument

--Humiditygenerator:high-accurancy,constant temperature an humidity test chamber: ChengFU.
--Standard:photoelectric point hygrometer of GE company
-- Voltage

5.ReliabilityTest

No,Item, Way, Requirment

1)      Impact test: make the sensor fall free form onemeter height to hard wood flooring three times. If the sensor is without bebroken or destroy, the electrical property is ok.
2)      Vibrating test: vibrating in X-Y-Z axis for 30seconds, Fequency with 10-55 HZ,Range:1.5mm,If the module is without being broken or destroy, the electrical property isok.
3)      Heating test: put the sensor in constanttemperaure 55℃ and humidity 3%RH for 1000 hours,acurrancy:±5%RH.
4)      High himidity: put the sensor in temperature 40 ℃and humidity 95% for 1000 hours, acurrancy: ±5%RH
5)      Temperaure test circurely: 300 timescircuration. Put in -10 ℃ for 1 hour per circuration; then upto 55 ℃and put for 1 hour; then continue another one circuration. acurrancy:±5%RH/±0.5℃.

Remarks:
1)      All datas are based on the temperature andhumidity changing range: with 80%RH
2)      After each test, the module shoule be put innormal evironmental temperature and humidity for 24 hours and then continueanother test.

6. Package

1)20pcs module per box.
2)Parameterlist.
3)Bulkpackage.Style availbale
4)Plastic caesavailable.

7.Remarks
1)Should not connect DC to sensitive compotentdirectly.
2)Shouldnot put compotent in conderastion and dry environment and below for long time.
A. Salt-fog B, acidic or oxidizing gases, such as sulfur dioxide, hydrochloricacid, etc.
3)Becausesensitive capacitance is PF,humicap capacity should not be welded off PCB andthen down-lead welded. Or it will lead to humidity value shift
4) Should not put in water to test. Or it will destroy senso

 