Detailed Product Description
Description:
- Classical appearance with useful function
- Professional design and quality for home and office
- Working voltage: DC 12V
- Card Capacity: 500 cards
- Password Capacity: 1 universal password; 500 individual passwords
- Working Temperature: 0 to 45 degrees C
- Working Humidity Range : 40% to 90%RH
- Door bell option
- Door Open Options (admin user selectable): Card (Key Tag) and Password/ Card (Key Tag) Only/ Password Only
- Dimension: Approx. 11.7cm x 11.7cm x 2cm / 4.6 x 4.6 x 0.8 inch
Instructions:
- The tables below show the way to operate this kit
- The default programming password is 990101
- The default unlock password is 1234
- The default card password is 0000
Function Setting |
Step 1 |
Step 2 |
Step 3 |
Step 4 |
Step 5 |
Modify Programming Password |
Press * |
Enter Programming Password |
Press 0 |
Enter 6 digit new password |
Enter the new password again |
Modify Unlock Time |
Press * |
Enter Programming Password |
Press 2 |
Enter 03 (TT=03 seconds) |
Press * to exit |
Modify Universal Password |
Press * |
Enter Programming Password |
Press 3 |
Enter 4 digit new password |
Press * to exit |
Add Valid Card |
Press * |
Enter Programming Password |
Press 5 |
Enter 3 digit new password (the password cant be repeated) |
Add card |
Delete Valid Card |
Press * |
Enter Programming Password |
Press 7 |
Enter the 3 digit password |
Delete card |
Function Setting
|
Step 1
|
Step 2
|
Step 3
|
Step 4
|
Unlock by Card or Password |
Press * |
Enter Programming Password |
Press 10 |
Press * to Exit |
Unlock by Card and Password |
Press * |
Enter Programming Password |
Press 11 |
Press * to Exit |
Turn Off Personal Password Modifying |
Press * |
Enter Programming Password |
Press 12 |
Press * to Exit |
Turn On Personal Password Modifying |
Press * |
Enter Programming Password |
Press 13 |
Press * to Exit |
Door Status Inspection |
Press * |
Enter Programming Password |
Press 60 / 61 |
Off / Om |
Alarm Status |
Press * |
Enter Programming Password |
Press 80 / 81 |
Off / On |
Alarm Time Setting |
Press * |
Enter Programming Password |
Press 82 |
Enter 03(TT= 3 seconds) |
Default Settings |
Press * |
Enter Programming Password |
Press 86 |
Default in 5 seconds |
Package Included:
- 1 x RFID Access control system
- 10 x Keyfob
- 5 x Screw
Keywords: Control access system, security access control, access control, access control systems
    
|