Detailed Product Description
Detailed Product Description
Keeping a specific dew point is the requirement for a troublefree plant operation. The mobile dew point measuring instrument
Technical data DP 300 |
Display single line |
dewpoint (ºCtd resp. ºC)
relative humidity ( %RH)
temperature (ºC resp. ºF)
alternatively to the dewpoint further parameters can be displayed: ppmV/V, atmospheric dewpoint in ºC, g/m3, mg/m3, g/kg and ºF |
Display functions |
Max, Min, state of battery |
Measuring range |
-80 to 20 ºCtd
-20 to 70 ºC
0 up to 100 %RH |
Pressure range |
-1 up to 1.5 MPa standard
-1 up to 35 MPa high pressure version |
Accuracy |
typical ± 2 ºCtd at -40 ºCtd |
Power supply |
Internal chargeable storage battery (4 x 1.5 NiMh AAA)
for approx. 15 h continual operation.
Continual measurement with mains operation via recharger.
Display "Low batt" max. 2 hours remaining operating
time. |
Operating temperature |
0 to 50 ºC |
EMC |
DIN EN 61326 |
Screw-in thread |
G 1/2" stainless steel |
Housing |
Polycarbonate |
Transport temperature |
-20 ... +50 ºC |
|